Sign In | Join Free | My futurenowinc.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Patient Monitor Parts >

Biocare FM-801 Fetal Monitor Interface Board with 100Mbps Signal Transmission 100mm×60mm×1.6mm Size and 50g Weight

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Biocare FM-801 Fetal Monitor Interface Board with 100Mbps Signal Transmission 100mm×60mm×1.6mm Size and 50g Weight

Brand Name : Biocare

Model Number : FM-801

MOQ : 1 Piece

Price : USD

Payment Terms : T/T,Western Union,Paypal

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : Interface board

PN : 02047015-01 50205008-01

Condition : Used

Signal transmission rate : ≤100Mbps

Material : PCB substrate: FR-4 epoxy glass cloth

Delivery Method : By DHL or FedEx

Color : Green

Package : Carton

Size : 100mm×60mm×1.6mm

Weight : About 50g

Contact Now

Biocare FM-801 Fetal Monitor Interface Board 02047015-01 50205008-01

Biocare FM-801 Fetal Monitor Interface Board has two models: Side A and Side B, model numbers 02047015-01 and 50205008-01, respectively.

Different sides face different signal sources and have different functions.

Side A, model number 02047015-01, is the internal interface board, connecting to the main board and receiving and transmitting signals from it. It acts as a signal relay station, helping the main board organize signals and ensure orderly operation.

Side B, model number 50205008-01, primarily connects to external interfaces such as USB and Ethernet, responsible for transmitting monitoring data from the device to external devices and other uses.

Both sides of the interface board offer diverse functions, making them a valuable companion to the main board.

Key Features
  • 1. Centralized Internal Signal Relay

    The 02047015-01 centrally manages and transmits fetal heart rate/contraction waveform data and alarm signals output by the main board to the main board, improving internal signal management.

  • 2. Bidirectional External Data Interaction

    50205008-01 implements data exchange and export functions, enabling online query and transmission of electronic medical records.

  • 3. Functional Expansion

    Both interface boards feature reserved expansion channels for internal and external expansion. Internally, they can connect to a fetal heart rate playback module and a fetal movement marker module; externally, they can connect to a barcode scanner for automatic patient information entry and printer connection.

  • 4. Fault Isolation and Protection: Reduces Maintenance Difficulty and Risk

    The interface board's "middle layer" design isolates faults and protects core components.

Technical Specifications
Product name Interface board
PN 02047015-01 50205008-01
Compatible machine Biocare FM-801
Condition Used
Signal transmission rate ≤100Mbps
Material PCB substrate: FR-4 epoxy glass cloth
Color Green
Size 100mm*60mm*1.6mm
Weight About 50g
Connections 20-pin/16-pin gold-plated cable
Biocare FM-801 Fetal Monitor Interface Board with 100Mbps Signal Transmission 100mm×60mm×1.6mm Size and 50g WeightBiocare FM-801 Fetal Monitor Interface Board with 100Mbps Signal Transmission 100mm×60mm×1.6mm Size and 50g Weight
FAQ
  • Q1: The buttons on the FM-801 monitor display respond but no waveform is displayed. The display is normal, and the problem is unrelated.

    A1: It's most likely a problem with the LVDS signal transmission on the 02047015-01. After turning off the power, first check the LVDS cable for oxidation and looseness. Reseat it and then measure the LVDS signal output pins on the interface board (seek professional assistance). If there is no signal output, the interface board's signal conditioning circuit is faulty. If there is a signal but no display, and all cables are connected properly, the 02047015-01 interface board needs to be replaced.

  • Q2: When exporting a report through the USB port of the 50205008-01, the computer displays a "Device not recognized" message. Even replacing the USB cable doesn't work. What should I do?

    A2: It's most likely a problem with the interface board's USB circuitry or driver. If there's no physical damage to the USB port, the interface board's USB controller chip is faulty, and the 50205008-01 needs to be replaced.

  • Q3: The Ethernet port indicator light on the 50205008-01 is off, and the device cannot connect to the hospital network. I've checked the network cable and switch and found them to be working properly. What could be the problem?

    A3: It could be a problem with the Ethernet circuit. If the wiring is normal, check the Ethernet port's power supply voltage. If there is no voltage, the interface board's power supply circuit is faulty. If the voltage is normal, measure the continuity of the Ethernet port on the interface board. If there is no continuity, the Ethernet chip on the interface board is damaged and the 50205008-01 interface board needs to be replaced.

Ordering Information
Payment Methods Bank Transfer / PayPal / Western Union
Shipping Methods DHL / FedEx

Product Tags:

100Mbps Signal Transmission Fetal Monitor Interface Board

      

100mm×60mm×1.6mm Size Biocare FM-801 Interface Board

      

50g Weight Patient Monitor Interface Board

      
Wholesale Biocare FM-801 Fetal Monitor Interface Board with 100Mbps Signal Transmission 100mm×60mm×1.6mm Size and 50g Weight from china suppliers

Biocare FM-801 Fetal Monitor Interface Board with 100Mbps Signal Transmission 100mm×60mm×1.6mm Size and 50g Weight Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)